detection circuit.
Turn off the power. Disconnect the
harnesses U, V, and W.
(R11301)
Caution
NO
YES
YES
NO
NO
YES
Check with the inverter checker (∗).
Turn off the power and reconnect
the harnesses. Turn on the power
again and restart the system.
(Precaution before turning on the power again)
Make sure the power has been off for at least 30 seconds.
Correct the power supply or
replace the SPM or the
PM1.
(Replace the outdoor unit
PCB.)
∗ Inverter checker
Part No.: 1225477
Replace the compressor.
Replace it as required.
Replace the compressor.
Check the electronic
expansion valve.
Normal?
Emergency
stop without compressor
running?
System shut
down after errors repeated
several times?
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.