SiUS12-928_A Main Functions
Function and Control 36
1.8 NIGHT SET Mode
Outline When the OFF timer is set, the NIGHT SET Mode is automatically activated. The NIGHT SET
Mode keeps the airflow rate setting.
Detail The NIGHT SET Mode continues operation at the target temperature for the first one hour, then
automatically raises the target temperature slightly in the case of cooling, or lowers it slightly in the
case of heating. This prevents excessive cooling in summer and excessive heating in winter to
ensure comfortable sleeping conditions, and also conserves electricity.
Cooling
Duct-Free System
Slim Duct Built-in System
Heating
(R11588)
Target temperature
0.5˚C (0.9˚F)
0.5˚C (0.9˚F)
TIMER operation
NIGHT SET Mode ON
0.5˚C (0.9˚F)
0.5˚C (0.9˚F)
(R12293)
+0.5˚C (0.9˚F)
+0.5˚C (0.9˚F) temperature shift
Target temperature remains the same
NIGHT SET Mode ON
TIMER operation
Operation stops
at the set hours
1 hour
30 minutes
temperature shift
When the outdoor temperature is normal and the
room temperature is at the set temperature.
When the outdoor temperature is high (27˚C (81˚F) or higher).
Target temperature
2˚C(3.6˚F)
(R10698)
Set temperature
Timer operation