11-13/16 (300mm) OR MORE
35-7/16 (900mm)
24-7/16 (620mm)
(SERVICE SPACE)
15-3/4 (400mm) OR MORE
(1-3/4) (45mm)
13/16 (20mm) OR MORE
SIGNAL TRANSMITTER
11/16 (18mm)
2-5/16 (58mm)
13/16 (20mm) OR MORE
(13/16)
1-1/2 (38mm)
2-3/4
ROOM TEMP.
35-7/16 (900mm)
SENSOR
(20mm)
(70mm)
24-7/16 (620mm)
19-11/16 (500mm)
OPERATION LAMP
(SUSPENSION BOLT PITCH)
CEILING
TIMER LAMP
4-3/4 (120mm)
< SERVICE SPACE >
(ALL AROUND)
INDOOR UNIT
7-3/8 (187mm)
22-φ 3/16 (φ 4.7mm) HOLES
ON/OFF SWITCH
9-1/2 (240mm) OR MORE
8
8xP.3-15/16 (100mm)=31-1/2 (800mm)
SIGNAL RECEIVER
CORD (LENGTH: 74-13/16)
37 (940mm)
( :1900mm)
(SUSPENSION BOLT PITCH)
2-3/8 (60mm)
(2-13/16) (72mm)
INFRARED RECEIVER UNIT
WIRELESS REMOTE CONTROLLER
34-5/8 (880mm)
(ARC452A23)
5-1/8 (130mm)
2-1/2 (63mm)
33-7/8 (860mm)
ARROW VIEW
3-9/16 (90mm)
3-9/16 (90mm)
4xP.5-7/8 (150mm)=23-5/8 (600mm)
INSPECTION DOOR
11-13/16 (300mm)
(CEILING OPENING)
SUSPENSION BOLT
21
4-UNC5/16 ~ 3/8
3-9/16 (90mm)
1-7/8 (47mm)
(M8 ~ M10)
20-M5 HOLES
1-15/16 (50mm)
13/16 (20mm)
2-1/4 (57.5mm)
13/16 (21mm)
3/8 (10mm)
1/2 (12.5mm)
10
(ALL AROUND)
6 (153mm)
6-5/16 (160mm)
7-1/16 (180mm)
7-7/8 (200mm)
6-11/16 (170 mm)
7
1-3/16 (30mm)
18-M4 HOLES
7xP.3-15/16 (100)=27-9/16 (700mm)
5-7/8 (150 mm)
13 (330mm)
(ALL AROUND)
5
3
30-11/16 (780mm)
3-15/16 (100 mm)
4
7/8 (23mm)
9
3-9/16 (90mm)
31-1/2 (800mm)
3-1/8 (80mm)
3-15/16 (100mm)
3-15/16 (100mm)
32-5/16 (820mm)
3-1/8 (80mm)
6-11/16 (170mm)
<IN CASE OF BACK-SUCTION>
20-M5 HOLES
PROTECTION NET10
(ALL AROUND)
AIR FILTER (ACCESSORY)
9
SUSPENSION BRACKET
8
3-15/16 (100mm)
POWER SUPPLY CONNECTION
7
INFRARED RECEIVER UNIT CONNECTION
6
1. IN CASE OF BACK-SUCTION,
NOTE)
10
CONTROL BOX5
MOUNT CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.
IN CASE OF BOTTOM-SUCTION,
6-5/16 (160mm)
I.D.φ 31/32 (φ 25mm) (OUTLET)
DRAIN HOSE (ACCESSORY)
4
7-7/8 (200mm)
7-1/16 (180mm)
6
MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.
SOCKET FOR DRAIN
VP20 O.D.φ 1-1/32 (φ 26mm)
3
2. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER
5-1/8 (130mm)
7xP.3-15/16 (100mm)=27-9/16 (700mm)
3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
/I.D.φ 25/32 (φ 20mm)
)(
SELECT ITS COLORIMETHOD (GRAVITY METHOD)
30-11/16 (780mm)
3-15/16 (100mm)
)
(
50% OR MORE.
GAS PIPE CONNECTION
φ 1/2 (φ 12.7mm) (FLARE CONNECTION)
2
31-1/2 (800mm)
3-9/16 (90mm)
9
3/8 (10mm)
IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY)
32-5/16 (820mm)
3-1/8 (80mm)
13/16 (20mm)
LIQUID PIPE CONNECTION
1
φ 1/4 (φ 6.4mm) (FLARE CONNECTION)
WHEN CONNECTING DUCT TO SUCTION SIDE.
1-15/16 (50mm)
< IN CASE OF BOTTOM-SUCTION >
NAME
DESCRIPTION
NUMBER
(IN CASE OF
BOTTOM SUCTION)
3D075268