DRAIN HOSE
(CONNECTING PART
O.D. φ5/8 (φ16mm)
THE HOSE LENGTH OF OUTSIDE
THE UNIT: ABOUT 18-5/16 (465mm))
SIGNAL
TRANSMITTER
11/16 (18mm)2-5/16 (58mm)
UP/DOWN
(AUTOMATIC)
FAN
COOLING, DRY
HEATING
15°
15°
25°
30°
7-3/8 (187mm)
25°
40°
75°
50°
60°
75°
70°
70°
WIRELESS REMOTE CONTROLLER
(ARC452A21)
41-5/16 (1050mm)
9-13/16 (250mm)
9-3/4 (248mm)
MIN.1-15/16 (50mm)
MIN.1-15/16 (50mm)
13-3/8 (340mm)
41-5/16 (1050mm)
9/16 (14.5mm)
1-3/8 (35.5mm)37-5/16 (947mm)
5/8 (16mm)
8-1/4 (210mm)
13-3/8 (340mm)
1-3/4 (45mm)
3-1/2 (89mm)2-9/16 (65mm)
1-3/4 (45mm)
45°
45°
THE MARK ( → )SHOWS PIPING DIRECTION
AIRFLOW (INDOOR)
REAR
LEFT
RIGHT
INCLUDING
INSTALLATION PLATE
(SPACE FOR
MAINTENANCE)
(SPACE FOR
MAINTENANCE)
REQUIRED SPACE
NAME PLATE
INTELLIGENT EYE SENSOR
BOTTOM
SIGNAL RECEIVER
LOUVERS
OPERATION LAMP
TIMER LAMP
INTELLIGENT EYE LAMP
INDOOR UNIT ON/OFF
SWITCH
MODEL NAME PLATE
BLADE ANGLES
RIGHT/LEFT (AUTOMATIC)
MIN.1-3/16 (30mm)
(SPACE FOR
PERFORMANCE)
FRONT
GRILLE
FIXING
SCREWS
(INSIDE)
TERMINAL BLOCK
WITH
GROUND TERMINAL
(INSIDE)
GAS PIPE φ1/2 (φ12.7mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 15-3/4 (400mm))
LIQUID PIPE φ1/4 (φ6.4mm) CuT
(THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 18-1/8 (460mm))
ROOM TEMP. THERMISTOR
(INSIDE)
WALL HOLE
φ3-1/8 (φ80mm) HOLE
WALL HOLE FOR EMBEDDED
PIPING φ3-1/8 (φ80mm) HOLE
STANDARD LOCATIONS OF WALL HOLES
( )
C: 3D074024A
SIGNAL TRANSMITTER
11/16 (18mm)
2-5/16 (58mm)
7-3/8 (187mm)
PROTECTION NET
10
AIR FILTER (ACCESSORY)
9
SUSPENSION BRACKET
8
POWER SUPPLY CONNECTION
7
INFRARED RECEIVER UNIT CONNECTION
6
CONTROL BOX
5
DRAIN HOSE (ACCESSORY)
4
I.D. φ31/32(φ25mm) (OUTLET)
SOCKET FOR DRAIN
VP20 (O.D. φ1-1/32 (φ26mm)/ I.D. φ25/32 (φ20mm))
3
GAS PIPE CONNECTION
2
LIQUID PIPE CONNECTION
1
φ1/4 (φ6.4mm) (FLARE CONNECTION)
φ3/8 (φ9.5mm) (FLARE CONNECTION)
NUMBER
DESCRIPTIONNAME
12(300mm) OR MORE
27-9/16(700mm)
(SERVICE SPACE)
24-7/16
(1-3/4) (45mm)
(620mm)
15-3/4 (400mm) OR MORE
9-1/2(240mm) OR MORE
13/16 (20mm) OR MORE
(13/16)
1-1/2 (38mm)
2-3/4
ROOM TEMP.
SENSOR
(SUSPENSION BOLT PITCH)
(20mm)
(70mm)
27-9/16
(700mm)
OPERATION LAMP
24-7/16(620mm)
19-11/16 (500mm)
TIMER LAMP
4-3/4 (120mm)
CEILING
8
INDOOR UNIT
ON/OFF SWITCH
(300mm)
11-13/16
SIGNAL RECEIVER
<<
SERVICE SPACE
>>
16-φ 3/16 (φ4.7mm)
5x(P3-15/16)=19-11/16
HOLE
(2-13/16) (72mm)
(P100mm)
INFRARED RECEIVER UNIT
(ALL AROUND)
ARROW VIEW
13/16 (20mm) OR MORE
2-3/8 (60mm)
29-1/8 (740mm)
INSPECTION DOOR
(CEILING OPENING)
(SUSPENSION BOLT PITCH)
16-M5 HOLES
SUSPENSION BOLT
(ALL AROUND)
5-1/8 (130mm)
3-9/16 (90mm) 23-5/8 (600mm)
26-3/4 (680mm)
2-1/2 (63mm)
26 (660mm)
22-13/16 (580mm)3-15/16 (100mm)
13/16 (20mm)
1-15/16 (50mm)
4x(P5-7/8)=23-5/8
2-1/4 (57.5mm)
3/8 (10mm)
13/16 (21mm)
1/2 (12.5mm)
10
12
(P150mm) (600mm)
9
4
7
1-3/16 (30mm)
14-M4 HOLES
5-1/2 (140mm)
5x(P3-15/16)=19-11/16
(ALL AROUND)
(P100mm) (500mm)
7/8 (23mm)
3
5
6 (153mm)
13 (330mm)
3-1/8 (80mm)
3-15/16 (100mm)
24-7/16 (620mm)
3-1/8 (80mm)
3-15/16 (100mm)
6-5/16 (160mm)
6-11/16 (170mm)
7-7/8 (200mm)
6-11/16 (170mm)
7-1/16 (180mm)
<<
IN CASE OF BACK-SUCTION
>>
(620mm)24-7/16
(600mm)23-5/8
9
7-1/16 (180mm)
6-5/16 (160mm)
3-15/16 (100mm)
7-7/8 (200mm)
6
3-1/8 (80mm)
10
3-9/16 (90mm)
3/8 (10mm)
5x(P3-15/16)=19-11/16
5-1/2 (140mm)
13/16 (20mm)
1-15/16 (50mm)
(P100mm) (500mm)
3-15/16 (100mm)
22-13/16 (580mm)
16-M5 HOLES
<<
IN CASE OF BOTTOM-SUCTION
>>
(ALL AROUND)
WIRELESS REMOTE CONTROLLER
(ARC452A23)
4-M8~M10
1. IN CASE OF BACK-SUCTION, MOUNT
CHAMBER COVER TO BOTTOM SIDE OF THE UNIT.
IN CASE OF BOTTOM-SUCTION,
MOUNT CHAMBER COVER TO BACK SIDE OF THE UNIT.
2. LOCATION OF UNIT'S NAME PLATE: CONTROL BOX COVER
3. MOUNT THE AIR FILTER AT THE SUCTION SIDE.
SELECT ITS COLORIMETHOD (GRAVITY METHOD)
50% OR MORE.
IT CAN NOT BE EQUIPPED WITH AIR FILTER (ACCESSORY)
WHEN CONNECTING DUCT TO SUCTION SIDE.
4. PIPE SPECIFICATION
NOTE)
()
CORD (LENGTH: 74-13/16)
( : 1900mm)
3-9/16 (90mm)
1-7/8 (47mm)
3D074619
(500mm)