FC 300 Profibus
Parameters
PROFIdrive profile [1]
Function:
Selects the interpretation of the control and status
words. The installed option in slot A determines the
valid selection.
8-50 C oasting Select
Option:
Digital input [0]
Bus [1]
Logic AND [2]
*
Logic OR [3]
Function:
Allows a choice between controlling the coasting
function via the terminals (digital inpu t) and/or via
the bus.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
8-51 Quick Stop Select
Option:
Digital input [0]
Bus [1]
Logic AND [2]
*
Logic OR [3]
Function:
Allows a choice between controlling the Quick stop
function via the terminals (digital inpu t) and/or via
the bus.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
8-52 D C Brake Select
Option:
Digital input [0]
Bus [1]
Logic AND [2]
*
Logic OR [3]
Function:
Allows a choice between controlling the DC brake
via the terminals (digital input) and/or via the bus.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] Digital and
control word.
8-53 Sta rt Select
Option:
Digital input [0]
Bus [1]
Logic AND [2]
*
Logic OR [3]
Function:
Choose between controlling the drive via the
terminals (digital input) and/or via the bus.
If you select Bus, you can only activate the
Start command if it is transmitted via the serial
communication port or fieldbus option. If you select
Logic AND, you must also activate the command via
one of the digital inputs. If you select Logic OR,you
can also activate the Start command via one of the
digital inputs.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0] D igital and
control word.
8-54 Reversing Select
Option:
Digital input [0]
Bus [1]
Logic AND [2]
*
Logic OR [3]
Function:
Choose between controlling the drive via the
terminals (digital input) and/or via the bus.
If you select Bus, you can only activate the
Reversing command if it is transmitted via the serial
communication port or fieldbus option. If you select
Logic AND, you must also activate the command via
one of the digital inputs. If you select Logic OR,
you can also activate the Reversing command via
one of the digital inputs.
NB!:
This parameter is active only when par.
8-01 Control Site is set to [0]
Digital and
control word.
59
MG.33.C2.02 - VLT is a registered Danfoss trademark