MAKING MODERN LIVING POSSIBLE
Operating Instructions
VLT
®
AutomationDrive FC 300, 0.25-75 kW

Table of Contents

Other manuals for Danfoss FC 300

Questions and Answers

  • L
    Luke TaylorAug 26, 2025
    How to fix drive overtemperature in Danfoss Media Converter?
    • K
      Karen AliAug 27, 2025
      If your Danfoss Media Converter is showing a drive overtemperature error, which could be due to a high ambient temperature or a motor cable that is too long, wait until the temperature of the heatsink is below 158°F [70°C].
  • S
    Sarah ConnerAug 27, 2025
    How to resolve DC overvoltage on Danfoss Media Converter?
    • N
      Nathaniel RochaAug 27, 2025
      If your Danfoss Media Converter shows a DC overvoltage error, which means the intermediate circuit voltage exceeds the limit, you can connect a brake resistor, extend the ramp time, or select the OVC function to extend the ramp times.
  • J
    Jennifer RodriguezAug 28, 2025
    How to troubleshoot DC undervoltage on Danfoss Media Converter?
    • K
      kgreenAug 28, 2025
      If your Danfoss Media Converter shows a DC undervoltage error, indicating that the intermediate circuit voltage has dropped below the “voltage warning low” limit, check whether the 24 V backup supply is connected and ensure the supply voltage matches the adjustable frequency drive.
  • M
    Mr. Elijah HowardAug 28, 2025
    What to do if Danfoss Media Converter brake resistor is short-circuited?
    • M
      Mary HigginsAug 28, 2025
      If the brake resistor has short-circuited in your Danfoss Media Converter, turn off the adjustable frequency drive and replace the brake resistor.
  • G
    Gabriel SharpAug 29, 2025
    What to do if Danfoss Media Converter has a brake chopper fault?
    • R
      Ronald SolisAug 29, 2025
      If the brake transistor has short-circuited in your Danfoss Media Converter, turn off the adjustable frequency drive and remove the brake resistor.
  • D
    Dana WeaverAug 30, 2025
    How to resolve control word timeout on Danfoss Media Converter?
    • Q
      qrobertsAug 30, 2025
      If there is no communication to the adjustable frequency drive of your Danfoss Media Converter, possibly increase par. 8-03 Control Word Timeout Time.
  • M
    Mrs. Teresa Bryant DDSAug 23, 2025
    What to do if there is a short-circuit in Danfoss Media Converter?
    • D
      David JensenAug 23, 2025
      If you encounter a short-circuit in the motor or on the motor terminals of your Danfoss Media Converter, turn off the adjustable frequency drive and remove the short-circuit.
  • E
    Ellen KingSep 1, 2025
    How to troubleshoot a dark or non-functional display on a Danfoss Controller?
    • B
      Brianna JacobsSep 1, 2025
      If the Danfoss Controller display is dark or has no function, first check the input power source. If the power source is okay, check for any missing or open fuses, or a tripped circuit breaker, following the provided recommendations. Another cause may be no power to the LCP; if this is the case, replace the faulty LCP or connection cable. Also, check for a shortcut on the control voltage (terminal 12 or 50) or at the control terminals and ensure the terminals are wired correctly. Verify you are using the correct LCP (LCP 101 (P/N 130B1124) or LCP 102 (P/N. 130B1107)). Adjust the contrast by pressing [Status] + ?/? to adjust the contrast. If the display (LCP) is defective, replace the LCP or connection cable. For an internal voltage supply fault or defective SMPS, contact your supplier.
  • K
    Kelly StewartSep 2, 2025
    What to do if the motor is not running with my Danfoss Controller?
    • N
      nwoodwardSep 2, 2025
      If the motor is not running, ensure the motor is connected and check the service switch. If you're using a 24 V DC option card, apply mains power to run the unit. If the LCP is stopped, press [Auto On] or [Hand On] (depending on your operation mode) to start the motor. Apply a valid start signal if there is a missing start signal (Standby). If the motor coast signal is active, apply 24 V on terminal 27 or program this terminal to No operation. If the reference signal source is wrong, program the correct settings and check the wiring, scaling of terminals, and reference signal.
  • J
    Joseph HoffmanSep 3, 2025
    Why is there a mains current imbalance greater than 3% in my Danfoss Controller?
    • R
      Robert PetersonSep 3, 2025
      If you notice a mains current imbalance greater than 3% in your Danfoss Controller, it could be due to a problem with the mains power. Try rotating the input power leads into the drive one position: A to B, B to C, C to A. It may also be a problem with the frequency converter unit, in which case you should also rotate the input power leads into the frequency converter one position: A to B, B to C, C to A.

Summary

Safety

Introduction

Purpose of the Manual

Explains the manual's scope, covering installation, startup, and operation.

Installation

Installation Site Check List

Lists essential checks for the installation location and environment.

Frequency Converter and Motor Pre-installation Check List

Outlines checks before installing the converter and motor.

Mechanical Installation

Covers procedures for physically installing the unit, including cooling and mounting.

Electrical Installation

Details all aspects of wiring the converter, including mains, motor, and control.

Safe Stop

Introduces the Safe Stop function and its safety aspects, including commissioning.

Start Up and Functional Testing

Pre-start

Covers procedures and checks before applying power.

Safety Inspection

Details critical safety checks before applying power.

Applying Power

Instructions for safely applying power to the unit.

Basic Operational Programming

Covers initial parameter setup for basic operation.

User Interface

Local Control Panel

Describes the LCP display and keypad functions for operation and programming.

Back Up and Copying Parameter Settings

Covers saving and transferring configuration data to/from the LCP.

Restoring Default Settings

Explains how to reset the converter to factory defaults.

About Frequency Converter Programming

Programming Example

Demonstrates programming for a common application using the quick menu.

Remote Programming with MCT 10 Set-up Software

Details using software for programming and analysis.

Warnings and Alarms

Warning and Alarm Definitions

Provides detailed explanations of specific warnings and alarms.

Basic Troubleshooting

Start Up and Operation

Offers solutions for common issues during initial startup.

Specifications

Specifications

Fuse Specifications

Provides recommendations for fuses and circuit breakers.

Branch Circuit Protection

Emphasizes protection against short-circuit and over-current.

Recommendations

Lists recommended fuse and breaker types by enclosure and power.

Danfoss FC 300 Specifications

General IconGeneral
EnclosureIP20
ApprovalscUL, UL, CE
EMC filterBuilt-in
Communication OptionsCANopen, PROFIBUS DP
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Output Voltage0-100% of supply voltage