Customer ports
Size 060 080 110 160 210 250
Axial and radial
1)
DN19 typ I DN25 typ I DN25 typ I DN32 typ I DN32 typ I DN32 typ I
Case drain ports
2)
0.875-14UN-2B
[
7
∕
8
-14UN-2B]
1.0625-12UN-2B
[1
1
∕
16
-12UN-2B]
1.313-12UN-2B
[1
5
∕
16
-12UN-2B]
Axial gauge ports
2)
0.875-14UN-2B
[
7
∕
8
-14UN-2B]
1.0625-12UN-2B [1
1
∕
16
-12UN-2B]
Gauge ports
2)
0.5625-18UNF-2B [
9
∕
16
-18UNF-2B]
1)
Split flange boss per ISO 6162, 40 MPa series.
2)
SAE O-ring boss
Operating parameters
Output speed
Features Unit
Size
060 080 110 160
210
250
Rated output
speed
max.displ. 32°
min
-1
(rpm)
3600 3200 2900 2600
2350
2200
min. displ. 6°
5900 5300 4800 4250
3850
3650
zero displ. 0°
6600 5950 5350 4750
4300
4050
Maximum output
speed
max. displ. 32°
4500 4100 3700 3300
3000
2800
min. displ. 6°
7250 6600 5950 5250
4800
4500
zero displ. 0°
7950 7200 6500 5750
5250
4900
System and case pressure, Ambient temperature
Parameter
Unit
All sizes
System pressure
Maximum working
bar [psi]
450 [6527]
Maximum
480 [6962]
Minimum above case pressure
(open and closed circuit)
See graphs in Required inlet pressure diagrams
(for cylinder block filling) on page 14.
Case pressure
Rated
3 [44]
Maximum
5 [73]
Minimum
0.3 [4]
Ambient
temperature
*
Maximum
°C [°F]
70 [158]
Minimum
-40 [-40]
*
Air temperature close to the unit
Technical Information
H1 Bent Axis Variable Displacement Motors, Size 060/080/110/160/210/250
Technical specifications
12 |
©
Danfoss | December 2016 11037153 | BC00000043en-US1103