Typical response times shown below at the following conditions: (continued)
Charge pressure
20 bar [290 psi]
Speed
1800 min
-1
(rpm)
Response time EDC 069/078
Stroking direction 0.8 mm [0.03 in] Orifice 1.3 mm [0.05 in] Orifice No orifice
Neutral to full flow 1.9 s 0.9 s 0.6 s
Full flow to neutral 1.6 s 0.9 s 0.5 s
Technical Information H1 Axial Piston Single Pumps, Size 069/078