EasyManua.ls Logo

Danfoss H1 - Operating Parameters H1 Tandem; Fluid Specifications; Viscosity and Temperature Range

Danfoss H1
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Forward-Neutral-Reverse electric control (FNR), options: A9 (12 V) and B1 (24 V)
The 3-position FNR control uses an electric input signal to switch the pump to a full stroke position.
Under some circumstances, such as contamination, the control spool could stick and cause the pump to
stay at some displacement. A serviceable 125 μm screen is located in the supply line immediately before
the control porting spool.
Forward-Neutral-Reverse electric control (FNR)
P003 193
FNR hydraulic schematic
P003 189
C2C1
F00A
M14
T PF00B
Pump displacement vs. electrical signal
P003 190E
100 %
“0“
100 %
Voltage VDC
Displacement
Control current
Voltage Min. current to stroke pump Pin connections
12 V 750 mA any order
24 V 380 mA
Connector
1 2
P003 480
Connector ordering data
Description Quantity Ordering number
Mating connector 1 Deutsch® DT06-2S
Wedge lock 1 Deutsch® W2S
Socket contact (16 and 18 AWG) 2 Deutsch® 0462-201-16141
Danfoss mating connector kit 1 K29657
Technical Information H1 Axial Piston Single Pumps, Size 069/078
Control options
11062169 • Rev 0700November 2015 23