0-01 Language
Option: Function:
[10] Chinese Part of language package 2
[20] Suomi Part of language package 1
[22] English US Part of language package 4
[27] Greek Part of language package 4
[28] Bras.port Part of language package 4
[36] Slovenian Part of language package 3
[39] Korean Part of language package 2
[40] Japanese Part of language package 2
[41] Turkish Part of language package 4
[42] Trad.Chinese Part of language package 2
[43] Bulgarian Part of language package 3
[44] Srpski Part of language package 3
[45] Romanian Part of language package 3
[46] Magyar Part of language package 3
[47] Czech Part of language package 3
[48] Polski Part of language package 4
[49] Russian Part of language package 3
[50] Thai Part of language package 2
[51] Bahasa
Indonesia
Part of language package 2
[52] Hrvatski Part of language package 3
NOTICE!
Parameter 1-20 Motor Power [kW], parameter 1-21 Motor
Power [HP], parameter 1-22 Motor Voltage and
parameter 1-23 Motor Frequency will not have eect
when parameter 1-10 Motor Construction = [1] PM, non-
salient SPM.
1-20 Motor Power [kW]
Range: Function:
Size
related*
[ 0.09 -
3000.00
kW]
Enter the nominal motor power in kW
according to the motor nameplate data.
The default value corresponds to the
nominal rated output of the unit.
Depending on the choices made in
parameter 0-03 Regional Settings, either
parameter 1-20 Motor Power [kW] or
parameter 1-21 Motor Power [HP] is made
invisible.
1-20 Motor Power [kW]
Range: Function:
NOTICE!
This parameter cannot be adjusted
while the motor is running.
1-21 Motor Power [HP]
Range: Function:
Size
related*
[ 0.09 -
3000.00
hp]
Enter the nominal motor power in HP
according to the motor nameplate data.
The default value corresponds to the
nominal rated output of the unit.
Depending on the choices made in
parameter 0-03 Regional Settings, either
parameter 1-20 Motor Power [kW] or
parameter 1-21 Motor Power [HP] is made
invisible.
NOTICE!
This parameter cannot be adjusted
while the motor is running.
1-22 Motor Voltage
Range: Function:
Size
related*
[ 10 -
1000 V]
Enter the nominal motor voltage
according to the motor nameplate data.
The default value corresponds to the
nominal rated output of the unit.
NOTICE!
This parameter cannot be adjusted
while the motor is running.
1-23 Motor Frequency
Range: Function:
Size
related*
[20 -
1000
Hz]
Select the motor frequency value from the
motor nameplate data. For 87 Hz operation
with 230/400 V motors, set the nameplate
data for 230 V/50 Hz. Adapt
parameter 4-13 Motor Speed High Limit [RPM]
and parameter 3-03 Maximum Reference to
the 87 Hz application.
NOTICE!
This parameter cannot be adjusted while the motor is
running.