6.4.17 21-** Ext. Closed-loop
Par.
No. #
Parameter description Default value
(SR = Size related)
4 set-up Change dur-
ing operation
Conver-
sion index
Type
21-0* Ext. CL Autotuning
21-00 Closed-loop Type [0] Auto 2 set-ups TRUE - Uint8
21-01 PID Performance [0] Normal 2 set-ups TRUE - Uint8
21-02 PID Output Change 0.10 N/A 2 set-ups TRUE -2 Uint16
21-03 Minimum Feedback Level -999999.000 N/A 2 set-ups TRUE -3 Int32
21-04 Maximum Feedback Level 999999.000 N/A 2 set-ups TRUE -3 Int32
21-09 PID Autotuning [0] Disabled All set-ups TRUE - Uint8
21-1* Ext. CL 1 Ref./Fb.
21-10 Ext. 1 Ref./Feedback Unit [1] % All set-ups TRUE - Uint8
21-11 Ext. 1 Minimum Reference 0.000 ExtPID1Unit All set-ups TRUE -3 Int32
21-12 Ext. 1 Maximum Reference 100.000 ExtPID1Unit All set-ups TRUE -3 Int32
21-13 Ext. 1 Reference Source [0] No function All set-ups TRUE - Uint8
21-14 Ext. 1 Feedback Source [0] No function All set-ups TRUE - Uint8
21-15 Ext. 1 Setpoint 0.000 ExtPID1Unit All set-ups TRUE -3 Int32
21-17 Ext. 1 Reference [Unit] 0.000 ExtPID1Unit All set-ups TRUE -3 Int32
21-18 Ext. 1 Feedback [Unit] 0.000 ExtPID1Unit All set-ups TRUE -3 Int32
21-19 Ext. 1 Output [%] 0 % All set-ups TRUE 0 Int32
21-2* Ext. CL 1 PID
21-20 Ext. 1 Normal/Inverse Control [0] Normal All set-ups TRUE - Uint8
21-21 Ext. 1 Proportional Gain 0.01 N/A All set-ups TRUE -2 Uint16
21-22 Ext. 1 Integral Time 10000.00 s All set-ups TRUE -2 Uint32
21-23 Ext. 1 Differentation Time 0.00 s All set-ups TRUE -2 Uint16
21-24 Ext. 1 Dif. Gain Limit 5.0 N/A All set-ups TRUE -1 Uint16
21-3* Ext. CL 2 Ref./Fb.
21-30 Ext. 2 Ref./Feedback Unit [1] % All set-ups TRUE - Uint8
21-31 Ext. 2 Minimum Reference 0.000 ExtPID2Unit All set-ups TRUE -3 Int32
21-32 Ext. 2 Maximum Reference 100.000 ExtPID2Unit All set-ups TRUE -3 Int32
21-33 Ext. 2 Reference Source [0] No function All set-ups TRUE - Uint8
21-34 Ext. 2 Feedback Source [0] No function All set-ups TRUE - Uint8
21-35 Ext. 2 Setpoint 0.000 ExtPID2Unit All set-ups TRUE -3 Int32
21-37 Ext. 2 Reference [Unit] 0.000 ExtPID2Unit All set-ups TRUE -3 Int32
21-38 Ext. 2 Feedback [Unit] 0.000 ExtPID2Unit All set-ups TRUE -3 Int32
21-39 Ext. 2 Output [%] 0 % All set-ups TRUE 0 Int32
21-4* Ext. CL 2 PID
21-40 Ext. 2 Normal/Inverse Control [0] Normal All set-ups TRUE - Uint8
21-41 Ext. 2 Proportional Gain 0.01 N/A All set-ups TRUE -2 Uint16
21-42 Ext. 2 Integral Time 10000.00 s All set-ups TRUE -2 Uint32
21-43 Ext. 2 Differentation Time 0.00 s All set-ups TRUE -2 Uint16
21-44 Ext. 2 Dif. Gain Limit 5.0 N/A All set-ups TRUE -1 Uint16
21-5* Ext. CL 3 Ref./Fb.
21-50 Ext. 3 Ref./Feedback Unit [1] % All set-ups TRUE - Uint8
21-51 Ext. 3 Minimum Reference 0.000 ExtPID3Unit All set-ups TRUE -3 Int32
21-52 Ext. 3 Maximum Reference 100.000 ExtPID3Unit All set-ups TRUE -3 Int32
21-53 Ext. 3 Reference Source [0] No function All set-ups TRUE - Uint8
21-54 Ext. 3 Feedback Source [0] No function All set-ups TRUE - Uint8
21-55 Ext. 3 Setpoint 0.000 ExtPID3Unit All set-ups TRUE -3 Int32
21-57 Ext. 3 Reference [Unit] 0.000 ExtPID3Unit All set-ups TRUE -3 Int32
21-58 Ext. 3 Feedback [Unit] 0.000 ExtPID3Unit All set-ups TRUE -3 Int32
21-59 Ext. 3 Output [%] 0 % All set-ups TRUE 0 Int32
21-6* Ext. CL 3 PID
21-60 Ext. 3 Normal/Inverse Control [0] Normal All set-ups TRUE - Uint8
21-61 Ext. 3 Proportional Gain 0.01 N/A All set-ups TRUE -2 Uint16
21-62 Ext. 3 Integral Time 10000.00 s All set-ups TRUE -2 Uint32
21-63 Ext. 3 Differentation Time 0.00 s All set-ups TRUE -2 Uint16
21-64 Ext. 3 Dif. Gain Limit 5.0 N/A All set-ups TRUE -1 Uint16
VLT AQUA Low Harmonic Drive Instruction
Manual
6 How to Program the Low Harmonic Drive
MG.20.T1.22 - VLT
®