5-96 Pulse Out #29 Timeout Preset
Range: Function:
0.00 %* [0.00 - 100.00 %] Set the output frequency transferred to the output terminal 29 when the terminal is configured as
'Bus Ctrl Timeout' in par. 5-63
Terminal 29 Pulse Output Variable
[48]. And a time-out is detected.
This parameter only applies for FC 302.
5-97 Pulse Out #X30/6 Bus Control
Range: Function:
0.00 %* [0.00 - 100.00 %] Set the output frequency transferred to the output terminal X30/6 when the terminal is configured
as 'Bus Controlled' in par. 5-66
Terminal X30/6 Pulse Output Variable
, Terminal X30/6 Pulse Output
Variable [45].
5-98 Pulse Out #X30/6 Timeout Preset
Range: Function:
0.00 %* [0.00 - 100.00 %] Set the output frequency transferred to the output terminal X30/6 when the terminal is configured
as 'Bus Ctrl Timeout' in par. 5-66
Terminal X30/6 Pulse Output Variable
[48]. And a time-out is
detected.
FC 300 Programming Guide 3 Parameter descriptions
MG.33.M8.02 - VLT
®
is a registered Danfoss trademark
115
3

Other manuals for Danfoss VLT AutomationDrive FC 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300
CategoryDC Drives
LanguageEnglish

Related product manuals