3.13 Parameters: Ethernet
3.13.1 12-0* IP Settings
12-00 IP Address Assignment
Option: Function:
Selects the IP Address assignment method.
[0] * Manual IP-address can be set in par. 12-01 IP Address.
[1] DHCP IP-address is assigned via DHCP server.
[2] BOOTP IP-address is assigned via BOOTP server.
12-01 IP Address
Range: Function:
[000.000.000.000 -
255.255.255.255]
Configure the IP address of the option. Read-only if par. 12-00 set to DHCP or BOOTP.
12-02 Subnet Mask
Range: Function:
[000.000.000.000 -
255.255.255.255]
Configure the IP subnet mask of the option. Read-only if par. 12-00 set to DHCP or BOOTP.
12-03 Default Gateway
Range: Function:
[000.000.000.000 –
255.255.255.255]
Configure the IP default gateway of the option. Read-only if par. 12-00 set to DHCP or BOOTP.
12-04 DHCP Server
Range: Function:
[000.000.000.000 –
255.255.255.255]
Read only. Displays the IP address of the found DHCP or BOOTP server.
NB!
A power-cycle is necessary after setting the IP parameters manually.
12-05 Lease Expires
Range: Function:
[dd:hh:mm:ss] Read only. Displays the lease-time left for the current DHCP-assigned IP address.
12-06 Name Servers
Option: Function:
IP addresses of Domain Name Servers. Can be automatically assigned when using DHCP.
[0] Primary DNS
[1] Secondary DNS
12-07 Domain Name
Range: Function:
Blank [0-19 characters] Domain name of the attached network. Can be automatically assigned when using DHCP.
12-08 Host Name
Range: Function:
Blank [0-19 characters] Logical (given) name of option.