3.21 Parameters: Sensor Input Option
3.21.1 35-0* Temp. Input Mode (MCB 114)
35-00 Term. X48/4 Temp. Unit
Select the unit to be used with temperature input X48/4 settings and readouts:
Option: Function:
[60] * °C
[160] °F
35-01 Term. X48/4 Input Type
View the temperature sensor type detected at input X48/4:
Option: Function:
[0] * Not Connected
[1] PT100 2-wire
[3] PT1000 2-wire
[5] PT100 3-wire
[7] PT1000 3-wire
35-02 Term. X48/7 Temp. Unit
Select the unit to be used with temperature input X48/7 settings and readouts:
Option: Function:
[60] * °C
[160] °F
35-03 Term. X48/7 Input Type
View the temperature sensor type detected at input X48/7:
Option: Function:
[0] * Not Connected
[1] PT100 2-wire
[3] PT1000 2-wire
[5] PT100 3-wire
[7] PT1000 3-wire
35-04 Term. X48/10 Temp. Unit
Select the unit to be used with temperature input X48/10 settings and readouts:
Option: Function:
[60] * °C
[160] °F
35-05 Term. X48/10 Input Type
View the temperature sensor type detected at input X48/10:
Option: Function:
[0] * Not Connected
[1] PT100 2-wire
[3] PT1000 2-wire
[5] PT100 3-wire
[7] PT1000 3-wire
FC 300 Programming Guide 3 Parameter descriptions
MG.33.M8.02 - VLT
®
is a registered Danfoss trademark
229
3