0.6
0.6
f
g
= 10 Hz
e75za293.11
Feedback
Disturbed feedback signal
t (Sec.)
t (Sec.)
Filtered feedback signal
Lowpass filter
Feedback
Illustration 74: Feedback Signal
Parameter 7-07 Speed PID Feedback Gear Ratio
Table 454: Parameter 7-07 Speed PID Feedback Gear Ratio
7-07 Speed PID Feedback Gear Ratio
Default value: 1
Parameter type: Range, 0.0001 - 32.0000
Setup: All setups
Conversion index: -4
Data type: Uint32
Change during operation: False
The drive multiplies the speed feedback by this ratio.
AU275636650261en-000101 / 130R0334258 | Danfoss A/S © 2022.12