Parameter 33-03 Velocity for Home Motion
Table 1171: Parameter 33-03 Velocity for Home Motion
33-03 Velocity for Home Motion
Default value: 10
Parameter type: Range, Size related
Setup: 2 setups
Conversion index: 0
Data type: Int32
Change during operation: True
This parameter defines the velocity of homing. It must not exceed parameter 32-80 Maximum Allowed Velocity.
Parameter 33-04 Behavior Duirng HomeMotion
Table 1172: Parameter 33-04 Behavior During HomeMotion
33-04 Behavior During HomeMotion
Default value: [0] Revers and index
Parameter type: Option
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Define the behavior when the home switch is found: Reversing without index (0 pulse) search, or forwarding without index search.
Option
Name
Description
[0]*
Revers and index
[1]
Revers no index
[2]
Forward and index
[3]
Forward no index
5.26.2 33-1* Synchronization
Parameter 33-10 Sync Factor Master
Table 1173: Parameter 33-10 Sync Factor Master
33-10 Sync Factor Master
Default value: 1
Parameter type: Range, -1073741824 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter 33-11 Sync Factor Slave
Table 1174: Parameter 33-11 Sync Factor Slave
33-11 Sync Factor Slave
Default value: 1
Parameter type: Range, -1073741824 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Int32
Change during operation: True
Parameter 33-12 Position Offset for Synchronization
Table 1175: Parameter 33-12 Position Offset for Synchronization
33-12 Position Offset for Synchronization
Default value: 0
Parameter type: Range, Size related
Setup: 2 setups
Conversion index: 0
Data type: Int32
Change during operation: True
AU275636650261en-000101 / 130R0334602 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 301 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 301 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 301
CategoryDC Drives
LanguageEnglish

Related product manuals