21/71 in this parameter are available. Instances 100/150 and 101/151 are Danfoss specific. Instances 20/70 and 21/71 are ODVA-
specific AC motor profiles. For guidelines in telegram selection, refer to the VLT® DeciveNet MCA 104 Installation Guide.
N O T I C E
A change to this parameter is executed immediately.
Option
Name
Description
[0]
Instance 100/150
[1]
Instance 101/151
[2]
Instance 20/70
[3]
Instance 21/71
[6]
Instance 102/152
Parameter 10-11 Process Data Config Write
Table 586: Parameter 10-11 Process Data Config Write
10-11 Process Data Config Write
Default value: Size related
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint16
Change during operation: True
Option
Name
Description
[-]
None
[109]
Mode of operation
[302]
Minimum reference
[303]
Maximum reference
[312]
Catch up/slow down value
[321]
Touch target
[322]
Master scale numerator
[323]
Master scale denominator
[326]
Master Offset
[328]
Master offset speed ref
[341]
Ramp 1 ramp up time
[342]
Ramp 1 ramp down time
[351]
Ramp 2 ramp up time
[352]
Ramp 2 ramp down time
[361]
Ramp 3 ramp up time
[362]
Ramp 3 ramp down time
[380]
Jog/homing ramp time jog ramp time
AU275636650261en-000101 / 130R0334 | 329Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide