Option
Name
Description
[238]
RS flipflop 8
[239]
RS flipflop 9
[240]
SL digital output A
[241]
SL digital output B
[242]
SL digital output C
[243]
SL digital output D
[244]
SL digital output E
[245]
SL digital output F
Parameter 13-52 SL Controller Action
Table 687: Parameter 13-52 SL Controller Action
13-52 SL Controller Action
Default value: Size related
Parameter type: Option, Array [20]
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Select the action corresponding to the SLC event. Actions are executed when the corresponding event (defined in parameter 13-51
SL Controller 1 Event) is evaluated as true.
Option
Name
Description
[0]
DISABLED
[1]
No action
[2]
Select set-up 1
Changes the active setup (parameter 0-10 Active Set-up) to 1. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[3]
Select set-up 2
Changes the active setup (parameter 0-10 Active Set-up) to 2. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[4]
Select set-up 3
Changes the active setup (parameter 0-10 Active Set-up) to 3. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[5]
Select set-up 4
Changes the active setup (parameter 0-10 Active Set-up) to 4. If the setup is changed, it merges
with other setup commands coming from either the digital inputs or via a fieldbus.
[10]
Select preset ref 0
Selects preset reference 0. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[11]
Select preset ref 1
Selects preset reference 1. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[12]
Select preset ref 2
Selects preset reference 2. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[13]
Select preset ref 3
Selects preset reference 3. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.
[14]
Select preset ref 4
Selects preset reference 4. If the active preset reference is changed, it merges with other preset
reference commands coming from either the digital inputs or via a fieldbus.