EasyManua.ls Logo

Danfoss VLT AutomationDrive FC 301

Danfoss VLT AutomationDrive FC 301
722 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Option
Name
Description
[41]
Set digital out D high
[42]
Set digital out E high
[43]
Set digital out F high
[60]
Reset counter A
[61]
Reset counter B
[62]
Counter A (up)
[63]
Counter A (down)
[64]
Counter B (up)
[65]
Counter B (down)
Parameter 23-04 Occurrence
Table 1025: Parameter 23-04 Occurrence
23-04 Occurrence
Default value: [0] All days
Parameter type: Option, Array [10]
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Select which days the timed action applies to. Specify working/nonworking days in:
Parameter 0-81 Working Days.
Parameter 0-82 Additional Working Days.
Parameter 0-83 Additional Non-Working Days.
Option
Name
Description
[0]*
All days
[1]
Working days
[2]
Non-working days
[3]
Monday
[4]
Tuesday
[5]
Wednesday
[6]
Thursday
[7]
Friday
[8]
Saturday
[9]
Sunday
[10]
Day 1 of month
[11]
Day 2 of month
[12]
Day 3 of month
[13]
Day 4 of month
AU275636650261en-000101 / 130R0334 | 555Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 301

Related product manuals