EasyManuals Logo

Danfoss VLT Micro Drive FC 51 User Manual

Danfoss VLT Micro Drive FC 51
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
1 Introduction
1.1 Purpose of this Operating Guide
This Operating Guide provides information for safe installation and commissioning of the product. It is intended for use by qualied
personnel. Read and follow the instructions to use the drive safely and professionally. Pay particular attention to the safety instruc-
tions and general warnings. Always keep this Operating Guide available with the drive.
1.2 Trademarks
VLT
®
is a registered trademark for Danfoss A/S.
1.3 Additional Resources
Other resources are available to understand advanced drive functions and programming.
The Programming Guide provides greater detail on working with parameters and many application examples.
The Design Guide provides detailed information about capabilities and functionality to design motor control systems.
Instructions for operation with optional equipment and replacement of components.
Supplementary publications and manuals are available at:
www.danfoss.com.
1.4 Type Approvals and Certications
1.5 IT Mains
N O T I C E
IT MAINS
Installation on isolated mains source, that is IT mains. Maximum supply voltage allowed when connected to mains: 440 V.
As an option, Danfoss oers recommended line lters for improved harmonics performance. See chapter Options and Spare Parts.
1.6 Disposal
Do not dispose of equipment containing electrical components together with domestic waste.
Collect it separately in accordance with local and currently valid legislation.
AQ348848915086en-000101 / 130R0943 | 5Danfoss A/S © 2020.09
Introduction
VLT® Micro Drive FC 51
Operating Guide

Other manuals for Danfoss VLT Micro Drive FC 51

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT Micro Drive FC 51 and is the answer not in the manual?

Danfoss VLT Micro Drive FC 51 Specifications

General IconGeneral
EnclosureIP20
Output Voltage0-100% of supply voltage
AltitudeUp to 1000 m without derating
Power Range0.18-22 kW
Control MethodV/f
CommunicationModbus RTU
Protection FeaturesOver-voltage, under-voltage, over-current, over-temperature
Ambient Temperature-10°C to 50°C
Storage Temperature-25°C to 65°C
Relative Humidity5-95% (non-condensing)
Input Voltage200-240 V, 380-480 V
Braking FunctionIntegrated braking chopper (optional)

Related product manuals