VLT
®
2800 Series
Introduction to VLT
2800
When the required parameter group has been
selected, each parameter can be chosen by
means of the [+ / -] keys:
FREQUENCY
001 LANGUAGE
ENGLISH
50.0 Hz
The 3rd line of the display shows the parameter
number and name, while the status/value of the
selected parameter is shown in line 4.
Changing data
Regardless of wh ether a parameter has been
selected under the Quick menu or the M e nu mode,
theprocedureforchangingdatawillbethesame.
Pressing the [CHANGE DATA] key gives access
to changing the selected parameter, following
which the underlini ng in line 4 wil l flash on the
display. The procedure for changing data depe nds
on w h ether the selected parameter represents a
numerical data value or a text va lue.
Changing a data value
If the selected parameter is a text value, the text
value is changed by means of the [+ / -] keys.
50.0 Hz
FREQUENCY
001 LANGUAGE
ENGLISH
The bottom d isplay line will show the value that will be
entered (saved) when acknowledgment is given [OK].
Changeofnumericdatavalue
If the selected pa rameter is represented by a numerical
data value, a digit is first chosen using the [< >] keys.
50.0 Hz
SETUP
1
FREQUENCY
130 START FREQUENCY
09.0 HZ
The selected digit can then be changed infinitely
variably using the [+ / -] keys:
50.0 Hz
SETUP
1
FREQUENCY
130 START FREQUENCY
10.0 HZ
The c hosen digit is indicated by the digit flashing. The
bottom display line shows the data value that will be
entered (saved) when signing off with [OK].
Manual initialisation
NB!:
Ma nual initialisation is n
ot possible on
the LCP 2 175N0131 control unit. It is,
however, possible to perform an initialisation
via par. 620 Operation mode:
The following parameters are not set to zero when
initialising vi a par. 620 Operation mode.
- par. 500 Address
- par. 501 Baud rate
- par. 600 Operat ing hours
- par. 601 Hours run
- par. 602 kWh counter
- par. 603 Number of power-ups
- par. 604 Number of overtemperatures
- par. 605 Number of overvoltages
- par. 615-617 Fault log
MG.28.E9.02 - VLT is a registered Danfoss trademark
37

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VT2800 Series and is the answer not in the manual?

Danfoss VT2800 Series Specifications

General IconGeneral
BrandDanfoss
ModelVT2800 Series
CategoryController
LanguageEnglish

Related product manuals