2800 Series
349 Speed comp delay
(SPEED COMP DELAY)
Value:
0 ms - 100 ms
10 ms
Function:
In this parameter the user can set the systems
delay t ime (Sensor, P LC, etc.). If you are running
speed-compensated stop, the delay time at
different frequencies has a major influence on
the way in which you stop.
Description of choice:
Thefactorysettingis10ms. Thismeansthatitis
assumed that the total delay from the Sensor, PLC
and other hardware corresponds to this setting.
NB!:
Only act ive for speed-compensated stop.
= factory setting. () = di splay text [] = value for use in communication via serial communicat ion port
MG.28.E9.02 - VLT is a registered Danfoss trademark