DS4800 REFERENCE MANUAL
4
4.3.3 ID-NET™ Network Termination
The network must be properly terminated in the first and last scanner of the network. This is
done by setting the ID-NET™ Termination Resistance Switch in the CBX100/500 to ON.
4.4 AUXILIARY RS232 INTERFACE
The auxiliary serial interface is used exclusively for RS232 point-to-point connections.
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular
communication modes such as LOCAL ECHO can be defined using the Genius™ utility
program or Genius™ based Host Mode Programming installed from the CD-ROM.
The 9-pin female Auxiliary Interface connector inside the CBX is the preferred connector for
device configuration or communication monitoring.
5
1
69
Figure 32 - 9-pin female connector
If permanent system wiring is required, the following pins are used to connect the RS232
auxiliary interface:
CBX100/500 Function
RX Auxiliary Interface Receive Data
TX Auxiliary Interface Transmit Data
SGND Auxiliary Interface Reference
RX TX
Reference
USER INTERFACE
Figure 33 - RS232 Auxiliary Interface Connections
NOTE
Do not connect the Aux Interface to the CBX spring clamp connectors and
the 9-pin connector simultaneously.
44

Table of Contents

Other manuals for Datalogic DS4800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DS4800 and is the answer not in the manual?

Datalogic DS4800 Specifications

General IconGeneral
BrandDatalogic
ModelDS4800
CategoryBarcode Reader
LanguageEnglish

Related product manuals