DS4800 REFERENCE MANUAL
5
EXTERNAL TRIGGER INPUT CONNECTIONS USING DS4800 POWER
EXTERNAL TRIGGER
DS4800
18
19
9
7
Ground
V
Signal
V
CC
~
~
+
-
Vdc
GND
I1A
I1B
Figure 58 - PNP External Trigger Using DS4800 Power
EXTERNAL TRIGGER
DS4800
Signal
18
19
9
7
Ground
V
V
CC
~
~
+
-
Vdc
GND
I1A
I1B
Figure 59 - NPN External Trigger using DS4800 power
EXTERNAL TRIGGER INPUT CONNECTIONS USING EXTERNAL POWER
DS4800
EXTERNAL TRIGGER
Vext 30 Vdc max.
18
19
V
CC
~
~
+
-
V
Signal
I1A
I1B
Figure 60 - PNP External Trigger Using External Power
DS4800
EXTERNAL TRIGGER
Vext 30 Vdc max.
18
19
Signal
V
V
CC
~
~
+
-
I1A
I1B
Figure 61 - NPN External Trigger Using External Power