EasyManua.ls Logo

Datalogic Gryphon L GD4300 - Code 128; Code 128 Enable;Disable; Expand Code 128 to Code 39

Datalogic Gryphon L GD4300
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENTER/EXIT PROGRAMMING MODE Code 128 Enable/Disable
Product Reference Guide 151
CODE 128
The following options apply to the Code 128 symbology.
Code 128 Enable/Disable
When disabled, the reader will not read Code 128 barcodes.
Code 128 = Disable
Code 128 = Enable
DEFAULT
Expand Code 128 to Code 39
This feature enables/disables expansion of Code 128 labels to Code 39 labels.
DEFAULT
Code 128 to Code 39 = Don’t Expand
Code 128 to Code 39 = Expand

Table of Contents

Other manuals for Datalogic Gryphon L GD4300

Related product manuals