References
310
Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Table 39
STEP ACTION EXAMPLES
1. Scan the ENTER/EXIT barcode
(Scanner enters Programming Mode)
2.
Determine placement of the 
Label ID charac
ters BEFORE or 
AFTER with regard to scanned 
data using 
Label ID 
Control, starting on page 82
Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix
3.
Scan the barcode selecting the 
symbology type 
you wish to 
designate label ID characters 
for using 
Label ID Symbology 
Selection, starting on page 83
.
DataBar
Omnidirectional
Code 39 Interleaved 2 of 5 Code 32
4.
Custom Label ID example 
(desired char
acters):
D   B    * = C 3 + P H
5.
Find hex equivalents from the 
ASCII Chart
(inside back 
cover), then scan in these 
digit
s/characters using the 
barcodes in the section: 
Keypad, starting on page 351
. 
If you make a mistake before 
the last 
character, scan the 
CANCEL barcode to abort and 
not save the entry string. You 
can then start again at the 
beginning.
44 42 2A 3D 43 33 2B 50 48
6. Scan the ENTER/EXIT barcode 
(Scanner exits Label ID entry)
7.
Scan the ENTER/EXIT barcode 
once again
(Scanner exits Programming Mode)
Result:
DB*[barcode 
data]
[barcode 
data]=C3
+[barcode data] [barcode data]PH
. Label ID Examples