1 MEMORX3
106
5
5 TECHNICAL FEATURES
5.1 TECHNICAL DATA
PHYSICAL CHARACTERISTICS
DIMENSIONS (LxWxH) 15.7 x 5.9 x 4.1 cm / 6.2 x 2.3 x 1.6 in
WEIGHT
(DEPENDING ON MODEL)
230 g / 7.76 oz (incl. 1430 mAH battery)
250 g / 8.81 oz (incl. 2300 mAH battery)
AUDIO
Rear Speaker for beeps and ringing tones
Microphone and Front Speaker
LEDS
Three-color Good Read, Keyboard and
Charging Status
DISPLAY
65
K Color TFT LCD with 320 x 240 pixel resolution
(QVGA), with LED backlight
and touch screen,
antiglare and antiscratch protection
KEYBOARD 25 Plastic Top - Backlit Keys + ON/OFF key
OPERATING
TEMPERATURE*
-10° to +50 °C / 14 °F to +122 °F (for models with
laser and 2D imager)
-10 to +45°C / 14 °F to +113 °F (for models with CCD
scan engine)
STORAGE TEMPERATURE -20° to +70 °C / -4° to +158 °F
HUMIDITY** 10 to 90% non-condensing for temperatures < 38 °C
DROP RESISTANCE*** 1.2 M / 3.9 FT
ENVIROMENTAL SEALING IP54
ESD PROTECTION 4 KV contact discharge, 8 KV air discharge
* Battery should be charged at an ambient temperature between 0 - 36º C to achieve the
maximum charging rate. Never charge the main device or spare batteries in a closed space
where excessive heat can build up.
Close to the limits of the working temperature, some display and/or battery performance
degradation may occur.
** Multiple rapid humidity and/or temperature variations may cause condensing.
*** Multiple drops can permanently damage the device.