4
4.3.1 Resetting the Memor X3
There are several reset methods for the Memor X3.
A warm boot terminates an unresponsive application and clears the working RAM,
but preserves both the file system and the registry.
A cold boot forces all applications to close and clears working RAM and files not
resident on the persistent flash memory. Registry is restored from persistent memory
if available or returned to factory default.
A clean boot restores the Memor X3 to factory configuration: registry and file system
return to factory default.
Warm Boot
Cold Boot
Clean
Boot
Registry
Preserved
Restored from flash (if available)
Factory
default
Flash Disk
(Backup Folder)
Preserved
Preserved
Clean
disk
RAM File System
Preserved
Factory default
Factory
default
Warm Boot
A warm boot closes all applications, clears the working RAM, but preserves the file
system and registry. If an application "hangs" initiate a warm boot to terminate the
application.
To perform a warm boot, press these keys simultaneously:
+

Table of Contents

Other manuals for Datalogic Memor X3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Memor X3 and is the answer not in the manual?

Datalogic Memor X3 Specifications

General IconGeneral
Display Size2.4 inches
RAM256 MB
ProcessorXScale PXA310 @ 806 MHz
Storage512 MB
Operating SystemWindows CE 6.0
Battery Capacity1430 mAh
ConnectivityWi-Fi, Bluetooth v2.1
Scanner2D Imager
Battery OptionsStandard and High Capacity
ProtectionIP54
Drop SpecificationWithstands drops from 1.2 meters
Operating Temperature-10 to 50 °C
Storage Temperature-20 to 70 °C

Related product manuals