Code 93
Product Reference Guide 309
Code 93 — cont.
Code 93 Check Character Transmission
Enables/disables transmission of an optional Code 93 check character.
Code 93 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
Code 93 symbology.
Variable Length —
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length —
For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
Code 93 Check Character Transmission = Disable
Code 93 Check Character Transmission = Enable
DEFAULT
ENTER/EXIT PROGRAMMING MODE
Code 93 Length Control = Variable Length
Code 93 = Fixed Length
DEFAULT