EasyManuals Logo

Datalogic PowerScan PM9500 User Manual

Datalogic PowerScan PM9500
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #267 background imageLoading...
Page #267 background image
RS-232 Parameters
Product Reference Guide
257
RS-232/USB COM Parameters
Intercharacter Delay
This parameter specifies the intercharacter delay between the end of one
character and the beginning of the next. The delay can be set within a range
of zero (0) to 990 milliseconds in 10ms increments. A setting of zero speci-
fies no delay.
To set the delay:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad
the
result with leading zeroes to yield two digits. For example: 0 = 00,
5 = 05, 20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MO
DE bar code to enter Program-
ming Mode.
4. Go to
page 31 and scan the bar code: SELECT INTERC
HARACTER
DELAY
SETTING.
5. Scan the appropriate two digits from the keypad in
Appendix D, Key-
pad
, that represent the duration which was determined in the steps
above. You will hear a two-beep indic
a
tion after the last character.
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See
Table 27 for some examples of how to
set this feature.
Table 27. Intercharacter Delay Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
50ms 150ms 600ms 850ms
2
Divide by 10 (pad with
leading zeroes to yield
two-digits)
05 15 60 85
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT INTERCHARACTER DELAY SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘5’ ‘5’ and ‘0 ‘6’ and ‘0’ ‘8’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic PowerScan PM9500 and is the answer not in the manual?

Datalogic PowerScan PM9500 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength680 nm
Sensor type-
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle-40 - 40 °
Light levels (direct sunlight)0 - 100000 lx
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, GS1 DataBar Expanded Stacked, GS1 DataBar Stacked Omnidirectional, MaxiCode, Micro QR Code, MicroPDF417, PDF417, QR Code
Wireless range150 m
Operating frequency910 MHz
Standard interfacesUSB, RS-232, RS-485
Connectivity technologyWireless
CertificationIEC 60825 Class 2 IEC 62471 Class 1 LED
Product colorBlack, Yellow
LED indicatorsYes
Protection featuresShock resistant
International Protection (IP) codeIP65
Sustainability certificatesRoHS
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-20 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Battery life10 h
Charging time4 h
Input voltage12 V
Battery capacity2150 mAh
Power consumption150 mA
Power source typeBattery
Cables includedNo
Weight and Dimensions IconWeight and Dimensions
Depth74 mm
Width110 mm
Height212 mm
Weight380 g

Related product manuals