Page #112 background imageLoading...
Page #112 background image
Exit and Save Configuration
ADVANCED FORMATTING
Ì$
106
DEFINE FIELD 1 BY:
EITHER
field separator
a)
ÌHG0`Î
Read the field separator character from the HEX table. Range of characters = 01-FE.
discard separator include separator
Ì01Î Ì12Î
OR
match character
b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 01-FE.
OR
field length
c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length.
OR
this is the last field (variable length)
d)
ÌHG2fÎ
AND
Field 1 Terminators
no field terminators
ÌHH0bÎ
1 field terminator 2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all
readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special
Key(s) on page 58.