QUICKSCAN
®
MOBILE
150
A HOST CONFIGURATION STRINGS
In this section we provide a description of how to modify the device configuration
using serial strings sent from the Host.
This method requires either the RS-232 or USB-COM interface.
The device configuration can be changed by receiving commands from the Host
through the serial interface. When this method is used, the programming sequence
format is the following:
Command
Character sequence in following tables
CR$-$+
Carriage return character (0D Hex.)
Enter configuration environment
Exit and Save configuration
Example:
Beeper tone 1
Beeper low intensity
BG1
$-
CR
Carriage return character (0D Hex.)
Exit and save new configuration
AC410132BH0
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
$+
Enter configuration environment
Multiple command programming sequence:
Each configuration parameter setting removes the condition previously active for that
parameter.
NOTE
The device buffer can contain about 400 characters. If your
programming string goes over this value, you must split it into separate
groups and send each group after a delay of at least 3 seconds to give
the reader time to empty the buffer and interpret the commands.

Table of Contents

Other manuals for Datalogic QuickScan Mobile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Mobile and is the answer not in the manual?

Datalogic QuickScan Mobile Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan Mobile
CategoryBarcode Reader
LanguageEnglish

Related product manuals