Enter Configuration Exit and Save Configuration
Ì$+;Î
CODE SELECTION
Ì$
84
2/5
F
AMILY
disable the family
ÌAC0QÎ
c Read the desired family code
d Read a check digit selection
Interleaved 2/5
ÌAC1TÎ
CHECK DIGIT TABLE
no check digit control
Normal 2/5 (5 Bars)
Ì12Î
ÌAC2WÎ
check digit control and transmission
Industrial 2/5 (IATA)
Ì23Î
ÌAC3ZÎ
check digit control without transmission
Matrix 2/5 (3 Bars)
Ì34Î
ÌAC4]Î
e Read 4 numbers for the code length
where:
First 2 digits = minimum code length.
Second 2 digits = maximum code
length.
The pharmaceutical code below is part of
the 2/5 family but has no check digit or
code length selections.
Code CIP/HR
The maximum code length is 99
characters.
The minimum code length must always
be less than or equal to the maximum.
ÌAC5`Î
French pharmaceutical code
Examples:
0199 = variable from 1 to 99 digits in
the code.
1010 = 10 digit code length only.

Table of Contents

Other manuals for Datalogic QuickScan Mobile

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan Mobile and is the answer not in the manual?

Datalogic QuickScan Mobile Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan Mobile
CategoryBarcode Reader
LanguageEnglish

Related product manuals