3.1.4 Sending Configuration Strings from Host
An alternative configuration method is provided in Appendix A using the RS-232 or
USB-COM interface. This method is particularly useful when many devices need to
be configured with the same settings. Batch files containing the desired parameter
settings can be prepared to configure devices quickly and easily.
3.2 QUICKSCAN
®
MOBILE STAND ALONE SETUP
Read the restore default parameters code below.
Restore QuickScan
®
Mobile Default
1.
Ì$+$*oÎ
2.
Read the codes below to set the radio address of the QuickScan
®
Mobile
reader.
Enter configuration
Ì$+;Î
Set Radio Address
3.
ÌRA0RFHÎ
+
four digits for the QuickScan
®
Mobile Address (from 0000 to 1999).
All readers used in the same area must have different addresses.
Exit and Save configuration
4.
Ì$-?Î
5.
Read the Bind code to pair the QuickScan
®
Mobile to the cradle.
The reader is dedicated to the cradle. Any previously bound reader will be
excluded.
Bind
Ì$+RN0$-IÎ
The yellow LED on the QuickScan
®
Mobile will blink; the reader is ready to be
positioned onto the cradle.