QUICKSCAN
®
MOBILE
138
4.4.5 Enter Sleep Timeout
For readers that have the Sleep state enabled, this timeout determines when the
reader will enter this state.
4.4.6 Standby
If this command is enabled, part of the CCD circuitry shuts down (Standby), in order
to optimize low power consumption when not reading. When the trigger is pressed
this circuitry powers up. This mode causes a minor delay of about 100 ms before the
reader is ready.
Standby is always enabled and is not configurable. To exit Standby press the trigger.
4.5 READING PARAMETERS
4.5.1 Hardware Trigger Mode
This mode determines how the reading phase is controlled when the hardware trigger
operating mode is selected:
• trigger active level: the reader goes ON when the trigger is pressed and goes
OFF when it is released
• trigger active pulse: the reader goes ON at the first trigger press and goes OFF
only at a second press
4.5.2 Trigger-Off Timeout
When this timeout is selected, the reader turns OFF automatically after the desired
period of time.
4.5.3 Reads per Cycle
In general, a reading cycle corresponds to the ON + OFF times of a device.
The resulting effects of this parameter on code reading depend on other related
configuration conditions. Here are the definitions of ON and OFF times.
• For readers using the software trigger parameter (FLASH MODE), a reading
cycle corresponds to the flash on + flash off times. Code reading takes place
during the flash on time.