64 H-Class
Communications (continued)
Menu Item Details
HOST SETTINGS
Sets host communication parameters, where:
HOST TIMEOUT
Sets the idle period before interface port timeout
occurs, where:
10 (1 – 60 SEC) Is the time (in seconds) that must elapse before
partially received formats will be ignored and the port
detection process repeated.
CONTROL CODES
Allows changes to the software command
interpretation controls, where:
STANDARD CODES
Sets these interpretation codes: Hex 01 = SOH
command; Hex 02 = STX command; count-by = ^;
Hex 1B = ESC; Hex 0x0D = Carriage Return
ALTERNATE CODES
Sets these interpretation codes: Hex 5E = SOH
command; Hex 7E = STX command; count-by = @;
Hex 1B = ESC; Hex 0x0D = Carriage Return
ALTERNATE CODES 2
Sets these interpretation codes: Hex 5E = SOH
command; Hex 7E = STX command; count-by = @;
Hex 1B = ESC; Hex 0x7C = Carriage Return
CUSTOM CODES
Sets interpretation codes, where:
SOH STX CR CNTBY
01 02 0D 5E
Are the codes according to your definitions.
;
Standard codes serve as default placeholders.
FEEDBACK CHARACTERS
Allows the return of printer codes, where:
ENABLED
Sends the host a Hex 1E (RS) after each label and a
Hex 1F (US) after each batch successfully prints.
DISABLED
Sends no feedback characters.
ESC SEQUENCES
Sets handling for data containing invalid ESC
sequences, where:
ENABLED
Processes commands normally.
DISABLED
Ignores ESC control codes during processing (as some
systems send “banners” to the printer).
;
Bitmapped font downloads will be disabled.