PROGRAMMER’S REFERENCE MANUAL
Appendix A: Intelhex Records.
Page 65
End record
This record must be the last record in a transfer.
Ll = 00
aaaa = 0000 (not used)
Tt = 01
Since the address field is not used by the printer the end record always has the form
:00000001ff