EasyManua.ls Logo

Datamax MP-Compact4 - Troubleshooting Common Issues; Problem Diagnosis and Solutions

Datamax MP-Compact4
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PROGRAMMER’S REFERENCE MANUAL
Label layout definition commands
Page 16
Barcode symbologies
Barcode symbology Barcode type, information
1
2
3
4
5
6
7
2 of 5 Interleaved – 2:1
2 of 5 Interleaved – 3:1
2 of 5 Interleaved – 5:2
2 of 5 Interleaved – 8:3
2 of 5 Interleaved – 13:5
2 of 5 Interleaved – 11:4
2 of 5 Interleaved – 7:3
Numeric code, variable length. If a check
digit is required, it can be inserted with the
%Z command. The code must contain an
even number of digits. The printer will
therefore insert a leading 0 if necessary.
If the 2:1 ratio is used, a minimum width
expansion of 4 is required.
11
12
13
14
15
16
17
Code 39 - 2:1
Code 39 - 3:1
Code 39 - 5:2
Code 39 - 8:3
Code 39 - 13:5
Code 39 - 11:4
Code 39 - 7:3
Alphanumeric code, variable length. If a
check digit is required, it can be inserted
with the %zC command (Code39 – modulo
43 checksum) or the %Z command
(EAN/UPC – modulo 10 checksum).

Table of Contents