W-Class 61
Advanced Entry Calibration (continued)
Step Operator Action Displayed Message Comment
11
Proceed according to
your media type:
Die-cut stock: strip the
media from the backing
and then reinsert it into
the sensor; adjust the
Sensor Eye Mark over
the center of the backing.
Notched stock: adjust
the Sensor Eye Mark
over the center of the
notch.
Reflective stock: Adjust
the Sensor Eye Mark
over the center of the
facedown black mark.
Press the key
to select the setting and
then record the sensor
reading in a table similar
to the one shown after
Step 12, as a TOF
Value.
Next, press the
key to increment the
Gain Number.
Repeat for each of the
Gain Numbers (00-32).
GAIN TRAN <yyy>
*00 (0 - 31)
Or, for reflective media:
GAIN REFL <yyy>
*00 (0 - 31)
Where ‘yyy’ is a
numerical value
representing the
current sensor
reading: useful in
locating the best
sensor position.
ã Note: Never
position the
sensor over a
perforation when
recording a
sensor reading.
ã Note: Do not move the position of the Media Sensor after it has been
adjusted.