88 W-Class
Electrical
Input Voltage: 90 – 132 or 180 – 264 VAC @ 47–63 Hz, auto-
ranging.
Grounding: Unit must be connected to a properly grounded
receptacle.
Power Consumption –
Typical Operating /
Standby:
127 Watts / 21 Watts W-6208
140 Watts / 21 Watts W-6308
162 Watts / 21 Watts W-8306
Environmental Requirements
Operating Temperature:
32° F – 104° F (0° C to 40° C)
Storage Temperature:
0° F 140° F (-17° C to 60° C)
Humidity:
10% 95%, non-condensing
Dust: Non-conducting, non-corrosive
Electromagnetic Radiation: Moderate RF fields can be tolerated
Mechanical
Height: 14.8” (38 cm)
Width: 13.8” (35 cm) W-6208, W-6308
16.1” (41 cm) W-8306
Depth: 18.5” (47 cm)
Weight: 55 lbs. (24.8 kg) W-6208, W-6308
65lbs. (29.3 kg) W-8306
Printing Specifications
Printing Type: Direct Thermal or Thermal Transfer
Print Speed: 2 – 6 IPS (50 – 152.4 mm/second) W-8306
2 – 8 IPS (50 – 203.2 mm/second) W-6208, W-6308
Printhead Resolution: 203 DPI (8 dots/mm) W-6208
300 DPI (11.8 dots/mm) W-6308, W-8306
Nominal Dot Size: .0043” X .0052” (.109 mm X .132 mm) W-6208
.00027” X .0043” (.069 mm X .108 mm) W-6308,
W-8306
Printhead Protection Type: Thermistor Sensor. Shutdown occurs at over-
temperature. When cooled, printing resumes
automatically.