TECHNICAL DATA
56
SH4 BASE-STANDARD
Auxiliary functions
* (depending on the model)
Restart / Test / EDM
Reset / EDM selection /auto-man selection
Muting / Override
Blanking
Anti-interference coding
Electrical protection
Class III
Connections
M12 5; 8; 12 poles
*(depending on the model)
Cable length (for power supply)
30 m max.
Pollution degree
2
a. The external voltage supply must be able to bridge main power failure of 20ms as specified in
IEC 60240-1.
OPTICAL DATA
Light source
Infrared LED (850 nm wavelength)
Resolution
14 mm - 30 mm - Body
Operating distance
0.2 to10 m for 14 mm res
0.2 to 20 m for 30 mm res
0.5 to 15 m for body (SHORT range)
5 to 70 m for body (LONG range)
EAA angle
< ±2.5° at 3 meters
Ambient light rejection
EN 61496-2-2020
MECHANICAL AND ENVIRONMENTAL DATA
Operating temperature
-30...+55 °C
Storage temperature
-30...+60 °C
Temperature class
T6
Humidity
15...95% (no condensation)
Mechanical protection
IP67, IP65 (EN 60529)
Vibrations
10 mm / 3g, 5 to 150 Hz frequency,
(EN 60068-2-6 / Class 3M7 IEC TR 60721-4-3)
Shock resistance
25g x 6 ms x 600
(EN 60068-2-27 / Class 3M7 IEC TR 60721-4-3)
Housing material
Painted aluminum (yellow RAL 1003)
Caps material
PBT Valox 553 black
Caps cover material
PBT 1403g3 blue (pantone 072C)
Frontal cover material
MAKROLON AR 7099 Clear
Weight
1.4 Kg/mt (single bar - without packaged)
ELECTRICAL DATA