EasyManuals Logo

Davis Instruments Vantage VUE Console Manual

Davis Instruments Vantage VUE
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #33 background imageLoading...
Page #33 background image
Calibrating, Setting, and Clearing Variables
29
To set a weather variable’s value:
1. Select the variable you wish to change (either RAIN or ET).
2. Press and release 2ND, then press and hold SET. The variable blinks.
3. Keep holding SET until all digits are lit and stop flashing. Release SET; only
one digit is now blinking.
4. Press the < or > keys to select digits in the value.
5. Press the + and - keys to add to or subtract from the selected digit.
6. When you are finished, press DONE to exit.
Clearing Weather Variables Accumulations & Calibrations
The following weather variables can be cleared:
Wind Direction—Clears the wind direction calibration.
Barometer — Clears any pressure offset used to calibrate the station.
Note: Clearing the barometric pressure offset value also clears the elevation setting in Setup
Mode. See “Screen 10: Elevation” on page 11.
Daily rain—Clearing the daily rain value is reflected in the daily rain total,
the last 15 minutes of rain, the last three hours of rain sent to the forecast
algorithm, the umbrella icon, and the monthly and yearly rain totals. Clear
the daily rain total if the station accidentally recorded rain when the ISS
was installed or after routine cleaning and maintenance.
Monthly rain — Clears the monthly rain total. Does not affect the yearly
rain total.
Yearly rain — Clears the yearly rain total.
Daily ET — Clears daily ET and subtracts the old daily ET total from the
monthly and yearly ET totals.
Monthly ET — Clears the current monthly ET total. Does not affect the
yearly ET total.
Yearly ET — Clears the current yearly ET total.
Heating and Cooling Degree Days— Clears the accumulated degree day
total.
To clear a single weather variable:
1. Select the weather variable. (For degree days, select outside temperature,
press WxCtr until degree days is displayed.)
2. Press and release 2ND, then press and hold CLEAR.
The variable you’ve chosen blinks. Keep holding
CLEAR until the value changes to zero or, in the case
of the barometer, the raw barometer value.
Clear All Command
This command clears all stored high and low weather data, including monthly
and yearly highs and lows, and clears alarm settings all at once.
1. Press WIND, making sure wind speed is displayed.
2. Press 2ND then press and hold CLEAR for at least six seconds.
3. Release CLEAR when “CLEARING NOW” displays at the bottom of the
screen.

Table of Contents

Other manuals for Davis Instruments Vantage VUE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Davis Instruments Vantage VUE and is the answer not in the manual?

Davis Instruments Vantage VUE Specifications

General IconGeneral
Console Display TypeLCD
Wind Direction Range0 to 360°
Wind Direction Accuracy±3°
Temperature Accuracy±1°F (±0.5°C)
Humidity Accuracy±3%
Solar Radiation Range0 to 1800 W/m²
Solar Radiation Accuracy±5%
UV Index Range0 to 16
Wireless Transmission Range1000 feet (300 meters)
Update Interval2.5 seconds
Temperature Range-40°F to +150°F (-40°C to +65°C)
Humidity Range0 to 100% RH
Rain Collector Resolution0.01 inches (0.2 mm)
Wind Direction Resolution
Power Source (Integrated Sensor Suite)Solar panel with battery backup
Power Source (Console)AC adapter or 3 C batteries
Wind Speed Accuracy±2 mph (±3 kph) or ±5%, whichever is greater
Rainfall Accuracy±4%
Operating Temperature-40°F to +140°F (-40°C to +60°C)
Wind Speed Range0 to 150 mph (0 to 241 km/h, 0 to 67 m/s)