PRELIMINARY
GAS HOOKUP
Flexible Line To Cooktop
Manual Shut-Off Valve
Must Be Easily Accessible
Verify the type of gas supplied to the location.
The cooktop is shipped from the factory set up
for Natural Gas or LP (propane), depending on
the specific model ordered. Verify that the
cooktop is compatible with the gas at the in-
stallation site before proceeding further. Re-
turn cooktop to dealer if the unit is not set for
site gas supply. A manual valve must be in-
stalled external to the appliance, in an acces-
sible location from the front for the purpose of
shutting off the gas supply. Make sure the gas
supply is turned off at the wall valve before con-
necting the appliance. The gas supply connec-
tions should be made by a qualified technician
and in accordance with local codes or ordi-
nances.
Locate Gas Supply and Electrical Supply, refer-
ring to the illustrations below.
Pressure Inches W.C.:
11.0~14.0″ - LPG
6.0~9.0″ - Natural Gas
COUNTER TOP
GAS SUPPLY
Installer supplied
shut-off valve must
be easily accessible
inside cabinetry
ELECTRIC SUPPLY
4 FOOT POWER CORD