PRELIMINARY
LP/NATURAL CONVERSION KIT INSTRUCTIONS
Before you begin, read these instructions
completely and carefully.
WARNING:
If the information in these instructions is
not followed exactly, fire, explosion or
production of carbon monoxide may re-
sult, causing property damage, personal
injury or loss of life.
This conversion kit must be installed by a
qualified service agency in accordance
with the manufacturers instructions. All
applicable codes and requirements of the
authority having jurisdiction must be fol-
lowed. The qualified service agency is re-
sponsible for the proper installation of
this kit. The installation is not proper and
complete until the operation of the con-
verted appliance is checked as specified
in the manufacturers instructions sup-
plied with the kit.
WARNING:
Before proceeding with the conversion,
shut off the gas supply to the appliance
prior to disconnecting the electrical
power. This is to prevent release of gas
during the conversion.
PARTS INCLUDED
Main Burner Orifice (5)
Simmer Burner Orifice (5)
Valve Bypass Jet (5)
Conversion Sticker (1)
Valve Stem C-Clip (5)
TOOLS NEEDED
1/8 Flat-blade Screwdriver
Adjustable Wrench
7mm Nut Driver
4mm Nut Driver (included)
Phillips Screwdriver
Ratchet with 1-1/16 Hex Deep Socket
25/32 Socket
Manometer