PRELIMINARY
ELECTRICAL SUPPLY
POWER REQUIREMENTS
120 VAC, 60 Hz., single phase.
CT-365: 0.10 Amp. Max.
(Use 15 Amp. Circuit minimum)
• Always disconnect the electric supply cord
from the wall outlet or service disconnect
before servicing this appliance.
• Observe all governing codes and ordinances
when grounding, in the absence of which, ob-
serve National Electrical Code ANSI/NFPA No.
70-1990.
RECOMMENDED GROUNDING
METHOD
This appliance is factory equipped with a power
supply cord with a three-prong grounding plug
(with polarized parallel blades).
The power supply cord must be plugged into a
mating grounding type receptacle, connected
to a correctly polarized 120 Volt circuit. If the
circuit does not have a grounding type recep-
tacle, it is the responsibility and obligation of
the installer or user to have the existing recep-
tacle changed to a properly grounded and po-
larized receptacle in accordance with all appli-
cable local codes and ordinances by a qualified
electrician. In the absence of local codes and
ordinances the receptacle replacement shall be
in accordance with the National Electrical Code.
THE THIRD GROUND PRONG SHOULD NOT,
UNDER ANY CIRCUMSTANCES, BE CUT OR RE-
MOVED. The electrical supply must be a 120
volt, 60 Hz single phase, 15 AMP circuit. The
power receptacle must be a NEMA 5-15R de-
vice to accept the three prong plug supplied
with the unit.
Third Ground Prong