Purpose
Interval
Procedure
5.6.8 Clean waste bucket
After every dispense, coffee residue (the coffee cake) is moved
into the waste bucket. Excess water from the brewer is captured
in a drip bucket, placed inside the waste bucket (B). If an
external waste bin is used, the waste bucket is replaced by a
waste guide (G) in combination with a fixed connection to the
waste water drain. The waste bucket / drip bucket or waste guide
needs to be emptied and cleaned regularly.
NOTE
If a fixed waste water connection is used, a drip bucket is not
needed.
Perform this procedure:
Daily (see Daily maintenance on page 47).
Perform the following steps:
1. Flip up the dispense arm with the outlet nozzles.
2. Depending on the used bucket types:
B) Remove the waste bucket (with the drip bucket inside
it) from the machine, or
G) Remove the waste guide from the machine.
3. Rinse the removed parts with clean warm water.
4. Dry parts completely.
55
Edge XNA Small Cabinet 18-000 CoEx XL® brewer User Manual 5DUXNQ20M EN V2.1