Table 97. Power-up LED sequence (continued)
MEM VTT EN. Waiting for MEM VTT PGs
CPU* VCCIO and PCIe clocks EN. Waiting for CPU VCCIO PGs
CPU* VCORE/VSA EN. Waiting for CPU* VCORE+VSA PGs
Waiting for NDC PG
Waiting for PCH PROCPWRGD
CPU* PG Asserted. SYS PWRGOOD Asserted
RUN State
PLTRST_N Asserted
CPU & MEM VR’s Shutdown
MAIN Rails Shutdown (7 seconds)
Table 98. NvDIMM LED sequence
NvDIMM
LED7 LED6 LED5 LED4 LED3 LED2 LED1 Description
RUN State – System operating normally
System powered down, NVsave in progress
NVsave complete. Asserting EMMC_PWROFF_NOTIFY_N to BMC
V_12V_SW powered down. System in G3, waiting for AC power
Table 99. System board LED sequence
Error
LED7 LED6 LED5 LED4 LED3 LED2 LED1 Description
B B Config Error: CPU1 present? DIMMs OK? Install DBG JMPR1 to bypass
B B B B CPU IERR
CPU COMBINED MCERR
B B B B B B B Thermal Issue on CPU* or MEM
B B B B B Internal VR Issue on CPU*
B B AUX Power Failsafe
Table 100. Pfault or failsafe errors LED sequence
Pfault or Failsafe Errors
LED7 LED6 LED5 LED4 LED3 LED2 LED1 Description
* B 12V Failure
* B 5V BP0 Failure
* B 5V BP1 Failure
* B 5V BP2 Failure
* B 3.3V A Failure
* B 3.3V B Failure
* B 5V SW Failure
* B 1.05V SW Failure
152 System diagnostics and indicator codes