Table 20. Standard operating temperature specications
Standard operating temperature Specications
Temperature ranges (for altitude less than 950 m or 3117 ft) 10°C to 35°C (50°F to 95°F) with no direct sunlight on the
equipment.
NOTE: Some congurations require a lower ambient temperature. For more information see the following
tables.
Table 21. Maximum continuous operating temperature for non-fabric dual processor conguration
TDP
(W)
Proces
sor
model
number
Suppor
ted
heat
sinks
Max
DIMM
count
per
CPU
12x
3.5”
HDDs
enclosu
re
8x 3.5”
HDDs
enclosu
re
4x 3.5”
HDDs
enclosu
re
24x
2.5”
HDDs
enclosu
re
20x
2.5”
HDDs
enclosu
re
16x
2.5”
HDDs
enclosu
re
12x
2.5”
HDDs
enclosu
re
8x 2.5”
HDDs
enclosu
re
4x 2.5”
HDDs
enclosu
re
No
back
plane
enclosu
re
205W
8180 CPU1:
FMM2
M |
CPU2:
V2DRD
CPU1: 6
| CPU2:
8
Not supported
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
30°C/
86°F
8180M CPU1:
FMM2
M |
CPU2:
V2DRD
CPU1: 6
| CPU2:
8
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
30°C/
86°F
8168 CPU1:
FMM2
M |
CPU2:
V2DRD
CPU1: 6
| CPU2:
8
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
21°C/
69.8°F
30°C/
86°F
200W
6154
CPU1:
FMM2
M |
CPU2:
V2DRD
CPU1: 6
| CPU2:
8
Not supported
22°C/
71.6°F
22°C/
71.6°F
22°C/
71.6°F
22°C/
71.6°F
30°C/
86°F
165W
6150 CPU1:
JYKMM
|
CPU2:
V2DRD
CPU1: 8
| CPU2:
8
Not supported
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
6146 CPU1:
JYKMM
|
CPU2:
V2DRD
CPU1: 6
| CPU2:
8
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
8176 CPU1:
JYKMM
|
CPU2:
V2DRD
CPU1: 8
| CPU2:
8
30°C/
86°F
30°C/
86°F
30°C/
86°F
35°C/
95°F
35°C/
95°F
22 Technical specications