5 Place the heat sink on the processor and push down on the base of the heat sink until the bracket locks onto the heat sink.
NOTE:
Ensure that the two guide pin holes on the bracket match the guide holes on the heat sink.
Do not press on the heat sink ns.
Ensure that the pin 1 indicator on the heat sink is aligned with the pin 1 indicator on the bracket before placing the heat
sink onto the processor and bracket.
Figure 38. Installing the heat sink onto the processor
Next steps
1 Install the processor and heat sink module.
2 Install the sled into the enclosure.
3 Follow the procedure listed in After working inside your system.
Related link
Installing a processor and heat sink module
Installing a sled
Removing the fabric and sideband cables
Prerequisites
NOTE
: The procedure to remove the carrier card is similar to installing an OCP card.
NOTE: Route the fabric cable for CPU 2 under the heat sink of CPU1.
1 Follow the safety guidelines listed in Safety instructions.
90
Installing and removing system components