Figure 26. Installing the linking board and SATA cable
Next steps
1 Install the support bracket.
2 Install the air shroud.
3 install the sled into the enclosure.
4 Follow the procedure listed in After working inside your system.
Related link
Installing the support bracket
Installing the air shroud
Installing a sled
Processor and heat sink module
CAUTION
: This is a Field Replaceable Unit (FRU). Removal and installation procedures must be performed only by Dell certied
service technicians.
NOTE: In a sled which has been congured with mixed CPUs – a fabric processor installed in the CPU2 socket and a non-fabric
processor installed in the CPU1 socket, you must connect the external Omnipath link cables to Port 2 on the OCP carrier card.
Use the following procedure when:
• Removing and installing a heat sink
• Replacing a processor
78
Installing and removing system components